Ultra-Broadband Operation Covers 20β700 MHz in a single module, eliminating the need for band-switching.
High Linear Output Power Delivers β₯49 dBm (β80 W) at 28 V and β₯49.5 dBm (β89 W) at 32 V, suitable for high-power transmission systems.
GaN Technology with High Efficiency Gallium nitride (GaN) design ensures high power density, low current draw (β€10 A @ 28 V, β€9 A @ 32 V), and improved thermal performance.
Wide Gain Adjustment Range Provides β₯25 dB of attenuation control with precise 1βdB step linearity, enabling flexible system integration.
Comprehensive RS485 Monitoring & Control Supports remote settings (on/off, gain) and real-time queries (status, temperature, output power) via standard RS485 interface.
Smart Thermal Management Built-in over-temperature protection with programmable threshold (+100 °C alarm/shutdown, +80 °C auto-recovery) ensures reliable operation in harsh environments.
Wide Operating Temperature Range Qualified for β40 °C to +55 °C, suitable for outdoor, industrial, and defense applications.
External Enable Control TTL-compatible EN pin with high-level disable (1.8β5 V) and low-level enable (0β0.5 V); floating defaults to normally ON for fail-safe operation.
Compact Mechanical Footprint Space-saving dimensions of 222 × 110 × 26 mm, facilitating integration into rack-mount or portable systems.
Standard RF Interfaces SMA input and N-type output connectors for easy cabling and system compatibility
GRQ-20-700M-100W-222110-(28β32V) GaN-EN-485
Test Signal: CW signal during test.
Supply Voltage: 28β32 V DC, GaN technology, dual-wire feed.
External EN Enable:
High level (DC +1.8 V to +5 V) β Disable
Low level (DC 0 V to +0.5 V) β Enable
Floating (open) β Default Normally ON.
Output Protection: No internal isolator; open-circuit at output is prohibited.
Output Connector: N-type female.
Items: | Quality Standards |
|---|---|
Operating Frequency Band: |
|
Max Gain: |
|
Maximum Output Power: |
|
Maximum Input Level: |
|
Gain Adjustment Range: |
|
Automatic Gain Control: |
|
Gain Adjustment Flatness: | At 10 dB attenuation: 1 dB step At 20 dB attenuation: 1 dB step At 25 dB attenuation: 1 dB step |
Operating Voltage: | 28 β 32 V DC, GaN, dual-wire power supply |
Operating Current: | @28 V: β€10 A; @32 V: β€9 A |
VSWR: | β€2:1 (to protect test equipment; output not tested) |
Operating Temperature Range: | -40ο½+55β |
Over-temperature Protection: | Shutdown at +100β; Recovery at 80β |
Baud Rate: | 19200 |
Monitoring Function: | RS485 interface communication
|
Connectors: | 2 connectors: Input β SMA (female); Output β N-type (female) |
Mechanical Dimensions: | 220 × 110 × 26 mm |
External EN Enable:
High level (DC +1.8V to +5V) β Disable (amplifier off)
Low level (DC 0V to +0.5V) β Enable (amplifier on)