Features:

  • High-Frequency Wideband Coverage: Operates from 2500 MHz to 6000 MHz, delivering ≥47 dBm (50W) output power from a single-stage GaN design.

  • Precise Step Attenuation: ≥25 dB gain adjustment range with excellent 1 dB step linearity at 10 dB, 20 dB, and 25 dB attenuation settings.

  • RS485 Remote Monitoring & Control: Enables real-time queries for module status, over-temperature alarm, amplifier temperature, and forward output power, plus remote on/off and gain control.

  • Comprehensive Protection Features: Over-temperature alarm/shutdown at +85°C with auto-recovery at +65°C (software configurable); output must not be left open-circuit (no isolator).

  • Compact & Low Power: Ultra-compact 222 × 85 × 25 mm housing with dual SMA connectors, drawing ≤5A at 32V, and supporting –40°C to +55°C operation.

Technical Specification:

Product Name:

  1. GRQ-2500-6000M-50W-22285-32VGaN-EN-485

Cautions

  1. CW Signal Testing

  2. Wideband power detection accuracy: ±3 dBm

  3. 32V, GaN, dual-wire power supply

  4. External EN (Enable) control:

    1. High level (DC +1.8V to +5V): Disable (amplifier off)

    2. Low level (DC 0V to +0.5V): Enable (amplifier on)

    3. Floating (no connection): Default on

  5. No isolator – output must not be left open-circuit

Items:

Quality Standards

Operating Frequency Band:

  1. 2500–6000 MHz

Max Gain:

  1. 52–57 dB (over full operating band)

Maximum Output Power:

  1. ≥47 dBm

Maximum Input Level:

  1. +5 dBm

Gain Adjustment Range:

  1. ≥25 dB

Automatic Gain Control:

  1. None

Gain Adjustment Flatness:

At 10 dB attenuation: 1 dB step

At 20 dB attenuation: 1 dB step

At 25 dB attenuation: 1 dB step

Operating Voltage:

32V, GaN, dual-wire supply

Operating Current:

≤5 A

VSWR:

≤2:1 (to protect test equipment; output not tested)

Operating Temperature Range:

-40~+55℃

Over-temperature Protection:

Shutdown at +85℃; Recovery at 65℃

Baud Rate:

19200

Monitoring Function:

RS485 interface communication

  1. Settings: On/off, gain

  2. Queries: Module status (including PA status, over-power alarm, over-temperature alarm), PA temperature, PA ATT value, downstream output power

  3. Over-power alarm: Triggered when power exceeds max output power +2 dB

  4. Over-temperature alarm: Recommended threshold at +85℃; Alarm and shutdown when temperature exceeds +85℃; Recovery at 65℃

  5. PA temperature detection: Range includes but not limited to -25℃~+85℃, accuracy ±3℃

  6. Downstream power detection: Total power detection, multi-tone signal test, range >20 dB, accuracy <±3 dB

Connectors:

2x SMA connectors

Mechanical Dimensions:

222 × 85 × 25 mm

Mechanical Drawing:

External EN Enable:

High level (DC +1.8V to +5V) – Disable (amplifier off)

Low level (DC 0V to +0.5V) – Enable (amplifier on)

Floating (no connection) – Default on.

Refer to the outline below for reference; actual dimensions are 230 × 120 mm.

Uziwave Communication Technology Co., Ltd. established on August 3, 2018, is a specialized manufacturer of RF products integrating R&D, production, and sales.

PRODUCT CATEGORY

QUICK LINKS

CONTACT US

 Email: uni@uziwave.com
 Technical Support: uni@uziwave.com
 WhatsApp/WeChat: +8615959207231
 Phone: +86-159-5920-7231
Add: Unit A356, 308, No. 16, Yunding North Road, Huli,District, Xiamen City
Copyright © 2026 Xiamen Uziwave Communication Technology Co., Ltd. All Rights Reserved.|Sitemap | Privacy Policy