UZI-TDD-960-1215M-200W-20070-EN-CPU-VFA
UZIWAVE
| Availability: | |
|---|---|
| Quantity: | |
Specification of 200W 960-1215M-UZI-GRQ-with CPU-VFA
UZI-TDD-960-1215M-200W-20070-EN-CPU-VFA
Single-tone signal test. 28V power supply, GaN.
The power amplifier has no ALC control function.
External EN enable: Fast switching. High level (5V) = Disable (PA OFF), Low level = Enable (PA ON). Default state at power-up (floating) is Disabled (PA OFF).
Neither the temperature alarm nor the VSWR protection will shut down the power amplifier; they only provide early warning alerts.
The power amplifier features fast current-limiting (overcurrent) protection, implemented via hardware.
The power amplifier is equipped with an isolator and features an N-type output connector.
To protect the amplifier, please test the VSWR protection function according to the customer's required VSWR test range (33-50 dBm).
We are currently looking for EMC and EMI testing from connector manufacturers, which will take some time.
As for the ambient temperature testing, we still need to find an external agency to conduct the tests.
Items: | Quality Standards |
Operating Frequency: | 960-1215M |
Gain: | Uplink:≤ -1dB Downlink:52-55dB |
Gain Flatness: | ≤ 2dB |
VSWR | ≤ 1.5 (Input/Output) Return Loss: ≥ 14 dB |
Maximum Output Power : |
|
Input Power: | +3dBm |
PA Enable : |
|
Phase Noise: | -90dBc @100KHz Note: Waiting for test result. |
Third Order Intercept (IMD3 rejection) across the band: |
|
P1dB Output : | ≥ 50 dBm |
Efficiency : | ≥ 50 % GaN amplifier |
Operating Voltage: | 28 V, GaN |
Operating Current: | ≤ 12A |
Harmonics: | ≥ 40 dBc |
Spurious Signals : | ≥ 60 dBc |
Switching Time On/Off time : | <700 Nanoseconds, |
Antenna to RX, (RF settling time): | <700 Nanoseconds |
Antenna to RX insertion loss : | 1dB |
Antenna to RX path power handling : | ≥40dBm power without any damage |
PA to RX isolation: | 40dBc Note: We have completed the preliminary evaluation and it looks acceptable, but further testing is required. |
Input Isolation: | >50 dB |
Forward Power Monitoring : | (40mV/dB) Analog voltage output |
Reverse Power Monitoring: | (40mV/dB) Analog voltage output |
Reverse Power Alarm : | TTL output |
Operating Temperature: | -40°C to +85°C with heat-sink and airflow |
Temperature Monitoring: | 40mV/°C Analog Voltage output |
Temperature Alarm: | TTL output |
Connectors: | 3 connectors in total: Input - 2 SMA Connector & RX Connector; Output - N-type Connector |
Mechanical Dimensions: | 200×70×24.5mm |
DB-9 DC Connector Pin Assignments |
|